Print This Page

Solution 5 multifuel (S2) [SOL5MCE-S2]

Documentation

Title Document type BK number / revision Document date
User Guide Hamlet stove User Guide 540 / 4 01-08-2017
Declaration of Performance Solution 5 - -
Top

Dimensions

Height (mm): 522
Width (mm): 397
Depth (mm): 388
Depth into fireplace (mm): -
Height into fireplace (mm): -
Width into fireplace (mm): -
Min. width in fireplace - inset (mm): -
Depth of front fascia - Inset (mm): -
Lintel depth (mm): -
Height (from top to centre of rear flue) (mm): 424
Height of low canopy (mm): 140
Height of high canopy (mm): -
Height of stand (mm): 100
Total height with stand (mm): -
Height of log store (mm): -
Total height with log store (mm): -
Height of pedestal (mm): -
Total height with pedestal (mm): -
Depth (Back to centre of top flue) (mm): 94
Flue diameter (mm): 102
Flue outlet type:  
Weight - when packed (kg): 57
Weight - when unpacked (kg): -
Ideal log length (mm): 254
Ideal log diameter (mm): -
Top

Distances to combustibles

Min. combustible distance to rear (mm): 625
Min. combustible distance to rear - twin wall flue (mm): -
Min. combustible distance to sides (mm): 525
Min. combustible distance to sides - twin wall flue (mm): -
Min. combustible distance above (mm): 306
Please note: We recommend allowing for a minimum clearance of 100mm to non-combustible materials around the entire appliance.
Top

Features

Current Stove: No
New Product: No
Ecodesign Ready: No
Model version: 2
Wet or Dry stove: Dry
Burns wood fuel: Yes
Burns solid smokeless fuel: Yes
Gas stove: No
Suitable for Smoke Control Areas: No
Stove guarantee: Ten-year
Suitable for a 12mm constructional hearth: Yes
Suitable for direct air installation: No
Stove body type: Freestanding
Top

Output - Wood fuel

Output - wood (kW): 4.9
Output to room - wood - boiler stove (kW): -
Min. output - wood (kW): 1
Max. output - wood (kW): 5
Output to water - wood - boiler stove (kW): -
Output to water - wood - boiler stove (BTU): -
Nett Efficiency - wood (%): 74.7
Wood refuelling period:  
Typical wood fuel load to achieve nominal output (kWh/Kg): -
Mean CO Emission - wood (%): 0.58
Particulate Matter - wood (%): -
Mean CH (OGC) Emission - wood (%): -
Mean NOx Emission - wood (%): -
Mean Flue Gas Temperature - wood (deg. C): -
Flue Mass Gas Flow - wood (g/sec): -
Top

Output - Solid smokeless fuel

Output - solid (kW): -
Output to water - solid - boiler stove (kW): -
Output to water - solid - boiler stove (BTU): -
Nett Efficiency - solid (%): -
Typical solid smokeless fuel load to achieve nominal output (kWh/Kg): -
Particulate Matter - solid (%): -
Mean CH (OGC) Emission - solid (%): -
Mean NOx Emission - solid (%): -
Mean Flue Gas Temperature - solid (deg. C): -
Flue Mass Gas Flow - solid (g/sec): -
Top

Output - Gas

Output - gas (kW): -
Min. output - gas (kW): -
Max. output - gas (kW): -
Nett Efficiency - gas (%): -
Min. Nett Efficiency - gas (%): -
Max. Nett Efficiency - gas (%): -
NOx mg per kWh (mg/kWH): -
Top

Direct air information

Direct Air Connection fixed or optional:  
Direct Air Connection Position left to centre distance (mm): -
Direct Air Connection Position right to centre distance (mm): -
Direct Air Connection Position floor to centre distance (mm): -
Direct Air Connection Underneath Position distance from rear (mm): -
Direct Air Connection Positioned Dead Centre?: N
Direct Air Connection diagram type:  
Top

Output - CE Test Figures

CE RATED (nominal) OUTPUT kW: 5.1
CE RATED MIN OUTPUT kW: 1.0
CE RATED MAX OUTPUT kW: 6.5
CE RATED UNDERHEARTH TEMP (deg.C): 48.0
Top

Boiler Tappings

Boiler Tapping Measurement A (mm): -
Boiler Tapping Measurement B (mm): -
Boiler Tapping Measurement C (mm): -
Boiler Tapping Measurement D (mm): -
Boiler Tapping Measurement E (mm): -
Boiler Tapping Measurement F (mm): -
Boiler Tapping Measurement G (mm): -
Boiler Tapping Measurement H (mm): -
Boiler Tapping Measurement I (mm): -
Boiler Tapping Measurement J (mm): -
Boiler Tapping Measurement K (mm): -
Max Operating Pressure: -
Top

Parts list

  Code Name Type Quantity Optional Extra?
1) AFS3565 Handle (stainless Steel) Handles and Locks 1 No
2) AFS3810 Handle Assembly (stainless Steel) Handles and Locks 1 No
3) AFS1294 Fire Door Complete Door 1 No
4) ARA014 Arada Rope Kit 2 Arada Brand Accessories 1 No
5) AFS1214 Glass Kit Glass and related parts 1 No
6) AFS009A 4 Inch Flue Spigot Spigot 1 No
7) AFS009B 4 Inch Hot Plate Hot Plate 1 No
8) AFS1286 Throat Plate Throat Plate 1 No
9) AFS2995 Liner 210 X 230 X 25 Liner 2 No
10) AFS1059 Liner Set (rear) Liner 1 No
11) AFS1327 Grate Bar Support (gbs001) Grate Bar Support 1 No
12) AFS1412 +/- Bracket With Fixings Miscellaneous 1 No
13) AFS2705 Self Levelling Feet Feet 2 No
14) AFS001 Grate Bar Grate Bar 5 No
15) AFS1323 Comb With Extension Comb and Riddle Pull 1 No
16) AFS008 Operating Tool Operating Tool 1 No
17) AFS058 Ash Pan Ash Pan 1 No
18) AFS1190 Fuel Retainer Bar Fuel Retainer 1 No
19) AFS2460 Hinge (single - Right Hand) Hinge 2 No
20) AFS1368 Primary Air Controls Air Inlet 1 No
21) AFS1405 Airwash Knob Handles and Locks 1 No
22) ARA010 Arada Hot Glove Arada Brand Accessories 1 No
23) AFS1010 Glass Clips Glass and related parts 1 No
24) AFS1361 Gasket And Glass Clips Glass and related parts 1 No
6) AIB0 Add In Boiler - 1.8kw Add In Boiler 1 Yes
7) AFS1135 Floor Fixing Kit Accessories 1 Yes
8) AFS3165 Safety Handle Accessories 1 Yes

Last updated: 23rd November 2020