Print This Page

Ecoburn Plus 5 (G2b) [ECB5FPLUS-G2Bsn]

Documentation

Title Document type BK number / revision Document date
User Guide Aarrow User Guide 530 / 14 01-11-2016
Declaration of Performance Ecoburn Plus 5 - -
Product Fiche / Tech. Spec. Ecoburn Plus 5 - 28-06-2019
New User Guides Guide to Wood Burning - -
New User Guides Quick Start Guide - -
Installation Guide Room heater / Dry Stove Installation Guide 545 / 11 07-12-2018
Top

Dimensions

Height (mm): 550
Width (mm): 431
Depth (mm): 365
Depth into fireplace (mm): -
Height into fireplace (mm): -
Width into fireplace (mm): -
Min. width in fireplace - inset (mm): -
Depth of front fascia - Inset (mm): -
Lintel depth (mm): -
Height (from top to centre of rear flue) (mm): 431
Height of low canopy (mm): -
Height of high canopy (mm): -
Height of stand (mm): 136
Total height with stand (mm): 686
Height of log store (mm): 386
Total height with log store (mm): 936
Height of pedestal (mm): -
Total height with pedestal (mm): -
Depth (Back to centre of top flue) (mm): 102
Flue diameter (mm): 127
Flue outlet type:  
Weight - when packed (kg): 68
Weight - when unpacked (kg): 64
Ideal log length (mm): 300
Ideal log diameter (mm): -
Top

Distances to combustibles

Min. combustible distance to rear (mm): 375
Min. combustible distance to rear - twin wall flue (mm): -
Min. combustible distance to sides (mm): 300
Min. combustible distance to sides - twin wall flue (mm): -
Min. combustible distance above (mm): 381
Please note: We recommend allowing for a minimum clearance of 100mm to non-combustible materials around the entire appliance.
Top

Features

Current Stove: Yes
New Product: No
Ecodesign Ready: No
Model version: 3
Wet or Dry stove: Dry
Burns wood fuel: Yes
Burns solid smokeless fuel: Yes
Gas stove: No
Suitable for Smoke Control Areas: Yes
Stove guarantee: Lifetime
Suitable for a 12mm constructional hearth: Yes
Suitable for direct air installation: No
Stove body type: Freestanding
Top

Output - Wood fuel

Output - wood (kW): 4.9
Output to room - wood - boiler stove (kW): -
Min. output - wood (kW): 1
Max. output - wood (kW): 4.9
Output to water - wood - boiler stove (kW): -
Output to water - wood - boiler stove (BTU): -
Nett Efficiency - wood (%): 80.3
Wood refuelling period:  
Typical wood fuel load to achieve nominal output (kWh/Kg): -
Mean CO Emission - wood (%): 0.58
Particulate Matter - wood (%): -
Mean CH (OGC) Emission - wood (%): -
Mean NOx Emission - wood (%): -
Mean Flue Gas Temperature - wood (deg. C): -
Flue Mass Gas Flow - wood (g/sec): -
Top

Output - Solid smokeless fuel

Output - solid (kW): -
Output to water - solid - boiler stove (kW): -
Output to water - solid - boiler stove (BTU): -
Nett Efficiency - solid (%): -
Typical solid smokeless fuel load to achieve nominal output (kWh/Kg): -
Particulate Matter - solid (%): -
Mean CH (OGC) Emission - solid (%): -
Mean NOx Emission - solid (%): -
Mean Flue Gas Temperature - solid (deg. C): -
Flue Mass Gas Flow - solid (g/sec): -
Top

Output - Gas

Output - gas (kW): -
Min. output - gas (kW): -
Max. output - gas (kW): -
Nett Efficiency - gas (%): -
Min. Nett Efficiency - gas (%): -
Max. Nett Efficiency - gas (%): -
NOx mg per kWh (mg/kWH): -
Top

Direct air information

Direct Air Connection fixed or optional:  
Direct Air Connection Position left to centre distance (mm): -
Direct Air Connection Position right to centre distance (mm): -
Direct Air Connection Position floor to centre distance (mm): -
Direct Air Connection Underneath Position distance from rear (mm): -
Direct Air Connection Positioned Dead Centre?: N
Direct Air Connection diagram type:  
Top

Output - CE Test Figures

CE RATED (nominal) OUTPUT kW: 4.9
CE RATED MIN OUTPUT kW: 1.0
CE RATED MAX OUTPUT kW: 4.9
CE RATED UNDERHEARTH TEMP (deg.C): 61.2
Top

Boiler Tappings

Boiler Tapping Measurement A (mm): 255
Boiler Tapping Measurement B (mm): 264
Boiler Tapping Measurement C (mm): 347
Boiler Tapping Measurement D (mm): -
Boiler Tapping Measurement E (mm): -
Boiler Tapping Measurement F (mm): -
Boiler Tapping Measurement G (mm): -
Boiler Tapping Measurement H (mm): -
Boiler Tapping Measurement I (mm): -
Boiler Tapping Measurement J (mm): -
Boiler Tapping Measurement K (mm): -
Max Operating Pressure: -
Top

Parts list

  Code Name Type Quantity Optional Extra?
1) AFS2345 Fire Door Door 1 No
2) ARA014 Arada Rope Kit 2 Arada Brand Accessories 1 No
3) AFS1361 Gasket And Glass Clips Glass and related parts 1 No
4) AFS2350 Glass Kit Glass and related parts 1 No
5) AFS1010 Glass Clips Glass and related parts 1 No
6) AFS2775 Hinge (right Hand) Hinge 2 No
7) AFS2680 Primary Air Controls Air Inlet 1 No
8) AFS3575 Handle (stainless Steel) Handles and Locks 1 No
9) AFS3550 Handle Assembly (stainless Steel) Door 1 No
10) AFS009 5 Inch Flue Spigot Spigot 1 No
11) AFS3945 Rope Kit Door Rope 1 No
12) AFS010 5 Inch Hot Plate Hot Plate 1 No
13) AFS3380 Throat Plate Throat Plate 1 No
14) AFS2665 Liner Liner 2 No
15) AFS1328 Grate Bar Support Grate Bar Support 1 No
16) AFS2670 Liner Liner 2 No
17) AFS2375 Flexi Grate Bar - Small Grate Bar 7 No
18) AFS1955 Comb With Extension Comb and Riddle Pull 1 No
19) AFS3940 Base Heat Shield Accessories 1 No
20) ARA010 Arada Hot Glove Arada Brand Accessories 1 No
21) AFS2355 Fuel Retainer Fuel Retainer 1 No
22) AFS058 Ash Pan Ash Pan 1 No
23) AFS008 Operating Tool Operating Tool 1 No
2) AIB8 Add In Boiler - 2.0kw Add In Boiler 1 Yes
3) ADP56 5-6 Flue Increasing Adapter Accessories 1 Yes
4) AFS3645 Bolt Down Brackets (pair) Accessories 1 Yes
5) AFS151A Spigot 5 Inch Complete With Damper Flap And Handle Accessories 1 Yes
6) STAND-ECB5FPLUS Stand For Ecb5fplus Stand 1 Yes
7) LOG-ECB5FPLUS Logstore For Ecb5fplus Log Store 1 Yes
8) AFS3165 Safety Handle Accessories 1 Yes

Last updated: 23rd November 2020