Print This Page

(Aarrow) Acorn 5 stove technical information

Top

Dimensions

Height (mm): 483
Width (mm): 395
Depth (mm): 350
Depth into fireplace (mm): -
Height into fireplace (mm): -
Width into fireplace (mm): -
Min. width in fireplace - inset (mm): -
Depth of front fascia - Inset (mm): -
Lintel depth (mm): -
Height (from top to centre of rear flue) (mm): 388
Height of low canopy (mm): -
Height of high canopy (mm): -
Height of stand (mm): -
Total height with stand (mm): -
Height of log store (mm): -
Total height with log store (mm): -
Height of pedestal (mm): -
Total height with pedestal (mm): -
Depth (Back to centre of top flue) (mm): 96
Flue diameter (mm): 102
Flue outlet type:  
Weight - when packed (kg): 47
Weight - when unpacked (kg): -
Ideal log length (mm): 200
Ideal log diameter (mm): -
Top

Distances to combustibles

Min. combustible distance to rear (mm): -
Min. combustible distance to rear - twin wall flue (mm): -
Min. combustible distance to sides (mm): -
Min. combustible distance to sides - twin wall flue (mm): -
Min. combustible distance above (mm): -
Please note: We recommend allowing for a minimum clearance of 100mm to combustible materials around the entire appliance.
Top

Features

Current Stove: No
New Product: No
Ecodesign Ready: No
Model version: 1
Wet or Dry stove: Dry
Burns wood fuel: No
Burns solid smokeless fuel: No
Gas stove: No
Suitable for Smoke Control Areas: No
Stove guarantee:  
Suitable for a 12mm constructional hearth: No
Suitable for direct air installation: No
Stove body type:  
Top

Output - Wood fuel

Output - wood (kW): 5
Output to room - wood - boiler stove (kW): -
Min. output - wood (kW): -
Max. output - wood (kW): -
Output to water - wood - boiler stove (kW): -
Output to water - wood - boiler stove (BTU): -
Nett Efficiency - wood (%): 77.56%
Wood refuelling period:  1 hour
Typical wood fuel load to achieve nominal output (kWh/Kg): -
Mean CO Emission - wood (%): -
Particulate Matter - wood (%): -
Mean CH (OGC) Emission - wood (%): -
Mean NOx Emission - wood (%): -
Mean Flue Gas Temperature - wood (deg. C): -
Flue Mass Gas Flow - wood (g/sec): -
Top

Output - Solid smokeless fuel

Output - solid (kW): -
Output to water - solid - boiler stove (kW): -
Output to water - solid - boiler stove (BTU): -
Nett Efficiency - solid (%): -
Typical solid smokeless fuel load to achieve nominal output (kWh/Kg): -
Particulate Matter - solid (%): -
Mean CH (OGC) Emission - solid (%): -
Mean NOx Emission - solid (%): -
Mean Flue Gas Temperature - solid (deg. C): -
Flue Mass Gas Flow - solid (g/sec): -
Top

Output - Gas

Output - gas (kW): -
Min. output - gas (kW): -
Max. output - gas (kW): -
Nett Efficiency - gas (%): -
Min. Nett Efficiency - gas (%): -
Max. Nett Efficiency - gas (%): -
NOx mg per kWh (mg/kWH): -
Top

Direct air information

Direct Air Connection fixed or optional:  
Direct Air Connection Position left to centre distance (mm): -
Direct Air Connection Position right to centre distance (mm): -
Direct Air Connection Position floor to centre distance (mm): -
Direct Air Connection Underneath Position distance from rear (mm): -
Direct Air Connection Positioned Dead Centre?: N
Direct Air Connection diagram type:  
Top

Output - CE Test Figures

CE RATED (nominal) OUTPUT kW: -
CE RATED MIN OUTPUT kW: -
CE RATED MAX OUTPUT kW: -
CE RATED UNDERHEARTH TEMP (deg.C): -
Top

Boiler Tappings

Boiler Tapping Measurement A (mm): -
Boiler Tapping Measurement B (mm): -
Boiler Tapping Measurement C (mm): -
Boiler Tapping Measurement D (mm): -
Boiler Tapping Measurement E (mm): -
Boiler Tapping Measurement F (mm): -
Boiler Tapping Measurement G (mm): -
Boiler Tapping Measurement H (mm): -
Boiler Tapping Measurement I (mm): -
Boiler Tapping Measurement J (mm): -
Boiler Tapping Measurement K (mm): -
Max Operating Pressure: -
Top

Parts list

  Code Name Type Quantity Optional Extra?
1) AIB0 Add In Boiler - 1.8kw Add In Boiler 1 No
1) AFS1101 Fuel Retainer Fuel Retainer 1 No
1) AFS1015 Liner Set Liner 1 No
1) AFS001/OLD (obsolete) Grate Bar *old Style* (ngb1b) Grate Bar 1 No
1) AFS1117 Grate Bar Support Grate Bar Support 1 No
1) AFS1058 Liner Set (side) Liner 1 No
1) AFS048 Door Rope Kit Door Rope 1 No
1) AFS1126 (obsolete) Stove Operating Manual Miscellaneous 1 No
1) AFS1059 Liner Set (rear) Liner 1 No
1) AFS1018 Throat Plate Throat Plate 1 No
1) AFS1135 Floor Fixing Kit Accessories 1 No
1) AFS1149 Comb With Extension Comb and Riddle Pull 1 No
1) AFS1141 Liner Set Liner 1 No
1) AFS1232 Airwash Handle Handles and Locks 1 No
1) AFS001 Grate Bar Grate Bar 1 No
1) AFS1273 Ash Pan Ash Pan 1 No
1) AFGS064 Hot Plate 4 Inch For Gas Hot Plate 1 No
1) AFS008 Operating Tool Operating Tool 1 No
1) AFS150A Damper Flap 5 Inch With Handle Spigot 1 No
1) AFS1095 Glass Kit Glass and related parts 1 No
1) AFS009A 4 Inch Flue Spigot Spigot 1 No
1) AFS151A Spigot 5 Inch Complete With Damper Flap And Handle Accessories 1 No
1) AFS1096 Gasket And Glass Clips Glass and related parts 1 No
1) AFS009B 4 Inch Hot Plate Hot Plate 1 No
1) AFS204 Fire Door Handle Assembly Handles and Locks 1 No
1) AFS1097 Airwash Assembly Air Inlet 1 No
1) AFS047 Hinge Kit Hinge 1 No
1) AFS205 Handle (kooler To Touch) Handles and Locks 1 No
1) AFS1099 Complete Fire Door Door 1 No
1) AFS1010 Glass Clips Glass and related parts 1 No

Last updated: 10th February 2020