i500 G2

Image of Arada i500 G2 stove

[I500-G2SN] i500 G2 (I Series) technical information

Stove model code: I500-G2SN

Stove model production status: Discontinued

First produced: March 2018

Last produced: November 2022

Information last updated : 26/01/2023

Documentation

TitleDocument typeBK number / revisionDocument date
Cassette Stove Installation GuideInstallation GuideBK605 / rev426-01-2023
Guide to Wood BurningNew User Guides--
I Series(G2) Stove User GuideUser GuideBK530 / rev1503-01-2017
i500Product Fiche / Tech. Spec.-28-06-2019
iSeries (G2) Door Handle Installation GuideComponent Installation GuideBK741 / rev123-05-2019
iSeries Internal Damper Installation GuideComponent Installation GuideBK581 / rev106-11-2017
Quick Start GuideNew User Guides--

Dimensions

Height (mm):558
Width (mm):508
Depth (mm):407
Depth into fireplace (mm):351
Height into fireplace (mm):556
Width into fireplace (mm):508
Depth (from back to centre of top flue) (mm):100
Flue diameter (mm):127
Flue outlet type:Vertical Spigot
Weight - when packed (kg):75
Ideal log length (mm):350

Distances to combustibles

Min. combustible distance to sides (mm):150
Min. combustible distance above (mm):550
Please note: We recommend allowing for a minimum clearance of 100mm to non-combustible materials around the entire appliance.

Features

Ecodesign Ready:No
Model Series / Generation:2
Wet or Dry stove:Dry
Burns wood fuel:Yes
Burns solid smokeless fuel:Yes
Gas stove:No
Suitable for Smoke Control Areas:Yes
Stove guarantee:Lifetime
Suitable for a 12mm constructional hearth:No
Suitable for direct air installation:Yes
Stove body type:Cassette

Output - Wood fuel

Output - wood (kW):6.4
Min. output - wood (kW):2
Max. output - wood (kW):9
Nett Efficiency - wood (%):74.4
Mean CO Emission - wood (%):0.14
Particulate Matter - wood (%):21.0
Flue Mass Gas Flow - wood (g/sec):5.4

Direct air information

Direct Air Connection fixed or optional:Fixed
Direct Air Connection Underneath Position distance from rear (mm):90
Direct Air Connection Positioned Dead Centre?:Y
Direct Air Connection diagram type:B

Output - CE Test Figures

CE rated nominal output kW:6.4
CE rated min output kW:1.5
CE rated max output kW:9.0

Parts list

 CodeNameTypeQuantityOptional Extra?
1)AFS4417Complete Fire DoorDoor1No
2)AFS4418Glass SupportGlass and related parts2No
3)AFS4365Handle AssemblyHandles and Locks1No
4)AFS4385Hinge SetDoor2No
5)ARA019Arada Rope Kit 3 Door Rope1No
6)AFS4360Rope KitDoor Rope1No
7)AFS4423Glass KitGlass and related parts1No
8)AFS4375Internal DamperMiscellaneous1No
9)AFS2245Flue Spigot Spigot1No
10)VFS063Gasket Miscellaneous1No
11)AFS4421Throat PlateThroat Plate1No
12)AFS4400Liner 261 X 163 X 25 ShapedLiner1No
14)AFS4422Liner 432 X 173 X 25Liner1No
15)AFS2410Grate Bar Support Grate Bar Support1No
16)AFS4405Liner 261 X 247 X 25 ShapedLiner1No
17)AFS2375Flexi Grate Bar - Small Grate Bar10No
18)AFS4420Comb And Riddle PullComb and Riddle Pull1No
19)AFS4500Air Grit GuardAir Inlet2No
20)AFS3405Air SliderAir Inlet2No
21)ARA010Arada Hot Glove Arada Brand Accessories1No
22)AFS4419Fuel RetainerFuel Retainer1No
23)AFS2430Ashpan Ash Pan1No
24)AFS008Operating Tool Operating Tool1No