i400 G2

Image of Arada i400 G2 stove

[I400-G2SN] i400 G2 (I Series) technical information

Stove model code: I400-G2SN

Stove model production status: Discontinued

First produced: February 2018

Last produced: November 2022

Information last updated : 26/01/2023

Documentation

TitleDocument typeBK number / revisionDocument date
Cassette Stove Installation GuideInstallation GuideBK605 / rev426-01-2023
Guide to Wood BurningNew User Guides--
I Series(G2) Stove User GuideUser GuideBK530 / rev1503-01-2017
i400Product Fiche / Tech. Spec.-28-06-2019
iSeries (G2) Door Handle Installation GuideComponent Installation GuideBK741 / rev123-05-2019
iSeries Internal Damper Installation GuideComponent Installation GuideBK581 / rev106-11-2017
Quick Start GuideNew User Guides--

Dimensions

Height (mm):558
Width (mm):405
Depth (mm):407
Depth into fireplace (mm):351
Height into fireplace (mm):558
Width into fireplace (mm):405
Depth (from back to centre of top flue) (mm):100
Flue diameter (mm):127
Flue outlet type:Vertical Spigot
Ideal log length (mm):255

Distances to combustibles

Min. combustible distance to sides (mm):220
Min. combustible distance above (mm):700
Please note: We recommend allowing for a minimum clearance of 100mm to non-combustible materials around the entire appliance.

Features

Ecodesign Ready:No
Model Series / Generation:2
Wet or Dry stove:Dry
Burns wood fuel:Yes
Burns solid smokeless fuel:Yes
Gas stove:No
Suitable for Smoke Control Areas:Yes
Stove guarantee:Lifetime
Suitable for a 12mm constructional hearth:No
Suitable for direct air installation:Yes
Stove body type:Cassette

Output - Wood fuel

Output - wood (kW):4.9
Min. output - wood (kW):2
Max. output - wood (kW):8
Nett Efficiency - wood (%):77.1
Mean CO Emission - wood (%):0.19
Particulate Matter - wood (%):17.0
Mean Flue Gas Temperature - wood (deg. C):329
Flue Mass Gas Flow - wood (g/sec):4.6

Direct air information

Direct Air Connection fixed or optional:Fixed
Direct Air Connection Underneath Position distance from rear (mm):90
Direct Air Connection Positioned Dead Centre?:Y
Direct Air Connection diagram type:B

Output - CE Test Figures

CE rated nominal output kW:6.1
CE rated min output kW:1.5
CE rated max output kW:8.0

Parts list

 CodeNameTypeQuantityOptional Extra?
1)AFS4345Complete Fire DoorDoor1No
2)AFS4350Glass SupportGlass and related parts2No
3)AFS4365Handle AssemblyHandles and Locks1No
4)AFS4385Hinge SetDoor1No
5)ARA019Arada Rope Kit 3 Door Rope1No
6)AFS4360Rope KitDoor Rope1No
7)AFS4355Glass KitGlass and related parts1No
8)AFS4375Internal DamperMiscellaneous1No
9)AFS2245Flue Spigot Spigot1No
10)VFS063Gasket Miscellaneous1No
11)AFS4380Throat PlateThroat Plate1No
12)AFS4400Liner 261 X 163 X 25 ShapedLiner1No
14)AFS4410Liner 333 X 173 X 25Liner1No
15)AFS1328Grate Bar Support Grate Bar Support1No
16)AFS4405Liner 261 X 247 X 25 ShapedLiner1No
17)AFS2375Flexi Grate Bar - Small Grate Bar7No
18)AFS4500Air Grit GuardAir Inlet2No
19)AFS4395Comb And Riddle PullComb and Riddle Pull1No
20)AFS3405Air SliderAir Inlet2No
21)ARA010Arada Hot Glove Arada Brand Accessories1No
22)AFS4390Fuel RetainerFuel Retainer1No
23)AFS4370Ash PanAsh Pan1No
24)AFS008Operating Tool Operating Tool1No
1)TRIM026-G2Trim For I400 3 Sided - Wide (60mm) Matt BlackTrim1Yes
2)TRIM032-G2Trim For I400 4 Sided - Wide (60mm) Matt BlackTrim1Yes